型号
|
OTPSP-300-12
|
OTPSP-300-13.5
|
OTPSP-300-24
|
OTPSP-300-27
|
OTPSP-300-48
|
|
|
输出 |
直流输出电压 |
12V |
13.5V |
24V |
27V |
48V |
|
输出电压容差 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
|
额定输出电流 |
25A |
22A |
12.5A |
11A |
6.5A |
|
|
输出电流范围 |
0-25A |
0-22A |
0-12.5A |
0-11A |
0-6.5A |
|
|
输出功率 |
300W |
297W |
300W |
297W |
312W |
|
|
纹波及噪音 |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
240mVp-p |
|
|
直流电压可调范围 |
-17%,+10% |
±11% |
-17%,+10% |
±11% |
-15%,+17% |
|
|
启动、上升、保持时间 |
1500ms,50ms,20ms满载 |
|||||
|
输入 |
输入电压范围 |
88~264 VAC47-63Hz;124~370VDC |
||||
|
功率因数 |
PF>0.95/230VACPF>0.95/115VAC满载 |
|||||
|
交流输入电流 |
4.5A/115 VAC2.3A/230VAC |
|||||
|
效率 |
82% |
82% |
84% |
84% |
86% |
|
|
冲击电流 |
冷启动电流18A/115VAC36A/230VAC |
|||||
|
漏电流 |
<3.5mA/240VAC |
|||||
|
保护特性 |
过载保护 |
105%~135% |
||||
|
保护方式:恒定输出电流限制,自动恢复 |
||||||
|
过电压保护 |
115%~135% |
|||||
|
保护方式:打嗝模式复位:自动恢复 |
||||||
|
风机控制O.T.P |
RTH1 or RTH2≥50℃风机开,≤45℃风机关,≥70℃切断输出 |
|||||
|
环境 |
工作温度、湿度 |
-10℃~+50℃;20%~90 %RH |
||||
|
保存温度、湿度 |
-20℃~+85℃;10%~95 %RH |
|||||
|
抗震性 |
10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
|||||
|
安全 |
耐压性 |
输入输出间:3KVAC输入与地:1.5KVAC输出与地:0.5KVAC |
||||
|
绝缘电阻 |
输入输出间,输入与地,输出与地:100M Ohms / 500VDC |
|||||
|
符合标准 |
安全标准 |
符合UL1950,TUV EN60950 |
||||
|
EMC标准 |
符合EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
|||||
|
其它 |
重量 |
1.64Kg |
||||
|
包装 |
8pcs/14Kg/1.06 CUFT |
|||||
|
备注 |
1.所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。 2.纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。 3.容差是电压设定误差、电压调整率和电流调整率之总和。 4.本电源考虑做为一个器件安装在最终设备上,该设备必须重新确认它的EMC指标。 |
|||||